Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
0517-86918678
Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
Tel:0517-86918678
Fax:0517-86918679
Email:zhongweick@163.com
Post Encoding:211600

Shielding signal lines

信号屏蔽电缆.jpg
  • 信号屏蔽电缆.jpg
Shielding line is wrapped a layer of the outside of the conductor shielding layer, plays a role of a…

Description:

Products overview:
Shielding line is wrapped a layer of the outside of the conductor shielding layer, plays a role of anti-interference, general shield for the knitting of brass or copper (aluminum), shield grounding when use need, to foreign interference signal is the layer into the earth, and to avoid jamming signal into the inner conductor dry all at the same time reduce the wastage of the transmitted signal.Shielding line is fit for ac rated voltage up to and including 450/750 power electrical appliances, instrumentation and telecommunications equipment, etc.
This product standards: GB5023-85
Second, the shielding signal type and name:
RVV - copper PVF insulation, circular connection soft PVC sheathed wire.
RVVB - copper core PVC insulated, PVC sheathed flat soft wire connection.
RVV - 105 ℃, 105 ℃, PVC insulated copper heat-resisting, circular connection soft PVC sheathed wire.
RVP - 105 ℃ -- 105 ℃ polyvinyl chloride insulated copper heat-resisting, shielding soft wire (cable).
RVVP - 105 ℃, 105 ℃, PVC insulated copper heat-resisting, shielding the soft PVC sheathed wire (cable).
RVVB - 105 ℃, 105 ℃, PVC insulated copper heat-resisting, flat connection soft PVC sheathed wire.
Three, shielding signal lines using features:
Ac rated voltage: 300/500 to and including 450/750v.
Wire allowed working temperature for a long time:
- 25 ~ 70 ℃
- 25 ~ 105 ℃
The installation of wire temperature: not less than 15 ℃
Four, shielding line product structure:

Five, shielding line size reference data (specification) :
RVV RVVB 300/500V

The serial numberSome conclusions by nominal cross section
(mm2)
Wire core structureWire reference data

Dc resistance
Not when 20 ℃
Greater than Ω/KM

The number/single
Diameter (mm)
Nominal diameter
(mm)

The largest diameter
(mm)

The weight of the
(kg-km)
12 x 0.7542/0.156.67.646.0026.0
22 x 0.7542/0.154.2 by 6.65.0 by 7.643.4426.0
32 x 1.032/0.207.17.855.6619.5
42 x 1.548/0.208.18.873.4313.3
52 x 2.548/0.209.811.0110.807.89
63 x 0.7542/0.157.28.062.7626
73 x 1.032/0.207.58.472.3919.5
83 x 1.548/0.208.99.6101.5313.3
93 x 2.577/0.2010.711.5154.357.89
104 x 0.7542/0.157.88.677.5926
114 x 1.032/0.208.49.261.2319.5
124 x 1.548/0.209.911.0130.9413.3
134 x 2.577/0.2011.612.5192.487.89
145 x 0.7542/0.158.79.496.4826.0
155 x 1.032/0.209.111.0112.2919.5
165 x 1.548/0.2011.012.0164.2513.3
175 x 2.577/0.2012.914.0239.057.89


Browse:
Return To The Top

分享到: