ZW-LZ series The remote type metal tube rotameter Can be used for complex flow measurement and proce…
Description:
Productoverview:
ZW-LZ seriesThe remote type metal tube rotameterCan be used for complex flow measurement and process control environment and various medium conditions, suitable for the measurement of liquid and gas.According to the instructions, the applicable situation and the signal output form classification: pointer type, electric remote type, corrosion type, pressure type, jacket type, explosion-proof type.Support for liquid crystal display, the scene shows the cumulative, instantaneous flow, digital communication, site measurement parameters, the electric remote can output 0 ~ 10mA, 4 ~ 20mA standard analog signal, especially suitable for small diameter and low flow velocity medium measurement.
Two, work principle:
ZW-LZ series <strong> remote type metal tube rotameter</strong> is the medium to be measured through a conical measuring tube float from upper and lower ends of the differential pressure generated form the upward force, when the float was immersed in a fluid on the lift is greater than the weight of the float, the float will rise, annulus area increases, the annulus fluid velocity decreased immediately float the lower end of the differential pressure is reduced, to float upward force also decreases with, until the lift is equal to the weight of the float when immersed in a fluid, the float will stabilize at a certain height.The float position that corresponds to the size of the measured medium flow.A built-in magnet, the float with the medium moves up and down, with the movement of the float magnetic field changes.
A, for in situ, by rotary magnetic float and the local indicator in the inner magnetic coupling, rotate, and drives the pointer, through the dial indicates the size of the flow.
B, the intelligent, by a solid state magnetic sensor intelligent indicator in the magnetic field will change into electrical signal output by A/D transform, D/A microprocessor, LCD liquid crystal display to show the size and cumulative flow flow.
Three, application:
ZW-LZ series <strong> remote type metal tube rotameter</strong> is suitable for the measurement of liquid, gas.Widely used in petroleum, chemical, power, pharmaceutical, food, water treatment, etc..The complex, harsh environmental conditions, the flow measurement process and various medium conditions in.
Four, main features:
All metal structure design, solid type float flowmeter 1;
2, the conceptual design of the measuring tube independent indicator;
3, stainless steel, Hastelloy, titanium, PTFE material measurement system;
4, low pressure loss;
5, short stroke, small structure design, the total height of 250 meters;
6, the magnetic coupling structure to ensure data transmission, more stable signal;
7, insulation or heating jacket;
8, the vertical and horizontal installation, more suitable for different occasions;
9, suitable for small diameter and low flow velocity medium measurement;
10, reliable operation, low maintenance, long service life;
11, for the straight pipe section is not high;
12, wide flow ratio 10:1;
13, two large LCD display, optional field instantaneous / total flow rate display, with backlight;
14, single axis sensitive indicator;
15, non contact magnetic coupling transmission;
16, all metal structure, suitable for high temperature, high pressure and strong corrosive medium;
17, can be used in flammable and explosive occasions;
18, AC power supply, battery, two-wire 19, multi parameter calibration function;
20, with data recovery, data backup and power-off protection function.
Fifth, technical parameters:
Measuring range: water (2.5 ~ 6000) L/h; air (0.07 ~ 2000) m3/h (0.101025 MPa, 20 C).
The measuring tube material: General 1Cr18Ni9Ti, corrosion type Cr18Ni12Mo2Ti, 316L, F46 and other 316 lining.If users have special requirements can be a special order.
Output signal: the two-wire (4~20) mA, three wire (0~10) mA.
Linearity: 1%;
Power supply: 24 DC (1 +) V.
Power consumption: 25 mW.
Ambient temperature: - 25 to 55 DEG C.
The influence of temperature: 0.5%/10 degrees.
Load resistance: DC (0 - 10) mA (0 ~ 1) K; (4 ~ 20) mA (0 ~ 600).
Cable wiring: RVVP 3 * 28/0.15.
Explosion proof grade: Exib II 2CT5 (No. GYB03582U).
With safety gate type: LB906.
The electric remote transmitter: K5WI-I or ESK-I (wire).
Sixth, conversion indicator:
The converter is actually the height conversion taper pipe float into the corresponding volume scale.From the output signal: local display and remote signal output type:
1, local display type: by in situ indicator in the follow-up magnetic float and the inner magnetic coupling, and rotate, and the electric pointer by dial indicating the flow
2, intelligent remote type, by the intelligent indicator in the follow-up magnetic float and the inner magnetic coupling, rotate, and drives the magnet and the sensing pointer through a magnetic sensor magnetic field change into electrical signals by A/D conversion, digital filter, D/ microprocessor, A output, LCD liquid crystal display, to show the instantaneous flow and cumulative flow rate.
Troubleshooting seven fault:
1, check the alarm set value size SU.
2, check the deviation set D value can not be too large.
3, FUN function, logic function is correct.HA-A said the upper limit is logical.LA-A said the lower limit is.
4, circuit board failure, replace the board.
5, if the lcd barcode indicates the correct output, no action, the cathode can check the external power and external power supply is connected with the anode of instrument power supply.
If the metal tube rotameter jitter in use, according to the jitter amplitude to determine what kind of amplitude jitter.Divided into mild and moderate jitter jitter jitter and jitter.
1, a slight jitter due to fluctuations caused by the media.Can be used to increase the damping of the way to overcome.
2, moderate jitter caused by medium flow state: general.For general gas as the medium pressure instability caused by.The regulator or stabilizer to overcome or increase the damping of gas meter.
3, severe jitter: mainly due to medium gas pulsation, operation pressure instability or give users pressure, temperature, flow meter and the actual state does not have large differences over range instrument.
Note eight, the installation of the:
In 1, before the first installation flowmeter in the pipeline, dirt, impurities such as welding blowing clean, if the liquid contained solid impurities, should the corresponding filter is installed between the valve and the straight pipe.
2, shielding and grounding system: in order to ensure ideal electromagnetic compatibility, shielding and grounding is very important, especially the bus cable, cable as far as possible to make continuous shielding.
3, the safety zone, according to the requirements of conventional cable grounding as much as possible.
4, in dangerous places, to ensure that the whole range of bus safe places and dangerous enough, all the potential, in this case, multiple ground is very superior.
Nine, the measuring range and the pressure loss:
Decay path
Common path
measuring range
Zui high pressure loss
DN (mm)
DN (mm)
The air (m3/h)
Water (L/h)
The air (KPa)
Water (KPa)
Fifteen
Fifteen
0.05-0.5
1.6-16
Seven
Six point four
0.07-0.7
2.5-25
Seven point one
Six point five
0.11-1.1
4.0-40
Seven point two
Six point five
0.18-1.8
6.0-60
Seven point three
Six point six
0.28-2.8
10-100
Seven point five
Six point six
0.40-4.0
16-160
Eight
Six point eight
0.70-7.0
25-250
Ten point eight
Seven point two
1.00-10
40-400
Ten
Eight point six
1.60-16
60-600
Fourteen
Eleven point one
Twenty-five
-
80-800
-
Fourteen
Twenty-five
3.00-30
100-1000
Seven point seven
Seven
4.50-45
160-1600
Eight point eight
Eight
7.00-70
250-2500
Twelve
Ten point eight
11-110
400-4000
Nineteen
Fifteen point eight
Fifty
-
500-5000
-
Sixteen point two
Fifty
18-180
600-6000
Eight point six
Eight point one
25-250
1000-10000
Ten point four
Eleven
Eighty
40-400
1600-16000
Twelve point six
Seventeen
Eighty
50-500
2000-20000
Fifteen point five
Six point three
One hundred
75-750
2500-25000
Seventeen Point Two
Eight point one
One hundred
100-1000
4000-40000
-
Nine point five
One hundred and twenty-five
160-1600
6000-60000
-
Ten
One hundred and twenty-five
250-2500
8000-80000
-
Sixteen
One hundred and fifty
-
10000-100000
-
Twenty
300-3000
12-120m3/h
-
Twenty
400-4000
15-150m3/h
-
Twenty-five
10, encoding selection:
Specification code
Encoding instructions
The name of the factory
ZW
Zhongwei control
Instrument types
LZ
Metal tube rotameter
structural style
/
In the next
H1
The left into the right
H2
Right into the left out
AA
The side into the side
LA
The bottom side
S
Threaded connection
M
Clamp connection (sanitary polishing tube)
Size code
- XXX
Cases:FifteenExpressDN15
The measuring tube material
R1
1Cr18Ni9Ti,Three hundred and four
R0
0cr18Ni12M02Ti,Three hundred and sixteen
RL
316L
RP
(PTFEF-lined)
Ni
(HasloyHastelloyC)
Ti
(TitHXiumtitanium alloy)
Media type
L
liquid
G
Gas
working temperature
H1
- 40C-100C
H2
- 80C-250C
Rated pressure
One point six
1.6MPa
Four
4.0MPa
Sixteen
16MPa
Twenty-five
25MPa
Additional structure
O
nothing
Z
Damping type
T
Jacket
H
High temperature type
Y
High pressure type
Form indicator
M1
Local indication
M2
Intelligent
M3
Intelligent(Flameproof)
The output signal in the communication
N
nothing
A
4-20mA
H
4-20mA+Hart
Alarm controller
K1
The upper limit alarm
K2
Alarm
K12
The upper and lower limit alarm
Explosion proof type
E1
Intrinsically safeEXIaCT5Square shell
E2
FlameproofEXiibt4Park Housing
Power supply
Zero
24VDC(can be omitted)
Two
220VAC
Three
Three point sixVolt lithium battery
Eleven, design selection and ordering information:
1, please provide the pipe size, wall thickness, material requirements and accuracy requirements;
2, please provide a liquid or gas, such as the name, commonly used commonly used temperature, working pressure, common flow, density, viscosity etc.;
3, choose anti-corrosion type, should indicate the measured corrosion and concentration etc.;
4, if there are special to show, please contact our sales department.
Customer service service commitment:
1, our series of metal tube flowmeter series product quality problems within twelve months, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.