Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
Tel:0517-86918678
Fax:0517-86918679
Email:zhongweick@163.com
Post Encoding:211600
ZW-LZB/ (S Series) Plastic tube rotameter The main part of the cone tube are composed of AS, ABS pla…
Description:
Productoverview:
ZW-LZB/ (S Series)Plastic tube rotameterThe main part of the cone tube are composed of AS, ABS plastic, good corrosion resistance, has the characteristics of reasonable structure, small volume, light weight, cone tube is not easily broken, it brings great convenience to use.The products are widely used in chemical industry, environmental protection, food and other industrial sectors.The connection can be divided into: inserting, welding, threaded and flanged connections four.
Two, work principle:
ZW-LZB/ (S) series of plastic tube rotameter is mainly composed of a bottom enlarged glass tube and a cone with the fluid flow rate to move up and down a floater.The fluid flows through the cone bottom tube, buoyancy A fluid kinetic energy generated on the float lift S and fluid to float up, when the lift and buoyancy of A and S is equal to the gravity float G, float in the balance, stable at a certain height position, cone scale on the tube indicates that the fluid flow value.
The float position meter readings as shown in Figure 2:
(ZW-LZB) S meter cone tube smooth inner wall of the tube (see Figure 4), the diameter of more than DN15 float flowmeter, stable movement, through the guide rod; (ZW-LZJ-) S flowmeter has three guiding cone tube inner ribs, the float remained stable (see Figure 4).Through the meter diameter of DN10 or less connected by a hose, equipped with needle flow control valve; path DN15 flowmeter with flange connection.
Three, application:
ZW-LZB/ (S) series of plastic tube rotameter is mainly used for corrosive liquid and gas medium flow detection, such as acid, alkali, oxidant, (strong oxidizing acid, organic solvents and other corrosive gas or liquid medium flow detection.
Four, main features:
1, small pressure loss.In the process of using, can be fully utilized, without a lot of effort too much, all the pressure can be fully used, there will be no loss.
2, reliable performance.In operation, frequent failure will not ensure good operation.When people are in the process of using, don't worry about running for it.Good performance, high reliability, can be assured use.
3, simple structure, convenient installation and use.The structure is simple, the installation is very convenient, can be installed in a short period of time.
4, cheap.The price is very cheap, the price advantage.
Five, technical parameters:
1, size: DN2 ~ 100mm;
2, measuring range: water (20 C): 1L/h ~ 100m3/h, gas (101325Pa, 20 C): 16L/h ~ 3000m3/h;
6, working temperature: less than or equal to 120 DEG c;
7, connection: hose, metal pipe, flange (GB/T9119-2000);
8, material: flange, float, a guide rod, a supporting plate and bolt etc..
Six, installation instructions:
1, before installation, the foam support instrument within the tool pliers gently remove it, and then re install it, at the time of installation, should pay attention to the rubber gasket is mounted in the nozzle groove, to prevent Water Leakage.
2, flow interface, available supporting ABS or PVC plastic pipe, plastic pipe, bonding with special glue, is also connected by plastic method, and metal flange connection.
3, flow meter must be installed vertically, there should be no obvious inclination, the mounting height should be easy to float on the reading, reading, sight and float level should be.The general standard: the need for ideal flow meter Zui high flow 50%-70%, try not to use Zui high..
4, the instrument on the lower reaches of the import and export shall ensure that there are 5 times the diameter of straight pipe instrument.
5, by side fluid pressure must be stable, such as fluid force too unstable, will cause the float fluctuation cannot be measured correctly, flowmeter should set the buffer or setting device.
6, plastic tube rotameter should be installed vertically, the angle between the line and the plumb line flowmeter center should not exceed 5 degrees.
Seven, matters needing attention:
1, the instrument used, should slowly open the valve to open the upstream and downstream of the flowmeter, flow regulating valve.The instrument stop should be used to slowly close the upstream valve, then close the meter downstream flow regulating valve.
2, the instrument indication in line to see, according to the height of the float rises at the present value of float gauge reading.
3, when the cone tube and float dirt, should be cleaned.
Error 4, regular check meter, once beyond the prescribed error, should replace the float and cone tube, or re calibration to get better precision.
5, the measured fluid and flowmeter calibration medium is uniform, the need for showing the value according to the revised.Represented by the formula QS=QN = Qn = QS actual flow flowmeter showing the value of P n = flowmeter calibration medium density s = density of measured medium f = float material density.
Eight, specifications and measuring range:
Nominal diameterDNmm
Model
measuring range
(waterTwentyC)
The degree of accuracy
Allow the measured fluid condition
Temperature
pressureMPa
Fifteen
LZB-15S
Ten~100L/h
Four
Zero~Sixty
Less than or equal to 0.6
Sixteen~160L/h
Twenty-five~250L/h
Forty~400L/h
Sixty~600L/h
Twenty-five
LZB-25S
One hundred~1000L/h
One hundred and sixty~1600L/h
Two hundred and fifty~2500L/h
Three hundred~3000L/h
Fifty
LZB-50S
Zero point four~4mThree/h
Zero point six~6mThree/h
One~10mThree/h
One point six~16MThree/h
Sixty-five
LZB-65S
Five~25mThree/h
Eight~40mThree/h
Nine, appearance and installation dimensions are as follows: the unit connection:Mm
Model
size
Inserting pipe specifications
The welding pipe diameter
L
B1
B2
LZB-15S
Two hundred and eighty
Twenty-one
Forty-five
Fifteen
Twenty
LZB-25S
Three hundred and eighty
Thirty-two
Sixty-eight
Twenty-five
Thirty-two
LZB-50S
Four hundred and thirty
Sixty-three
Ninety-eight
Fifty
Sixty-five
LZB-65S
Four hundred and thirty
Seventy-five
One hundred and twenty-five
Sixty-five
Seventy-five
LZB-()S,LZB-()SDFigure type flowmeter
Ten,LZB-()SD(tube type) flowmeter specifications of main technical parameters are as follows:
Nominal diameterDNmm
Model
measuring range (waterTwentyC)MThree/h
The degree of accuracy
Allow the measured fluid condition
Temperature
pressureMPa
Twenty-five
LZB-25SD
Zero point one~One
Four
Zero~Sixty
Less than or equal to 0.6
Zero point one six~One point six
Zero point two five~Two point five
Thirty-two
LZB-32SD
Zero point four~Four
Zero point six~Six
Fifty
LZB-50SD
One~Ten
One point six~Sixteen
Eleven,LZB-()(SDTube type flowmeter) appearance and installation size: unit connection:Mm
Model
size
Inserting pipe specifications
The welding pipe diameter
L
B1
B2
ZW-LZB-25SD
Two hundred and thirty
Thirty-two
Sixty
Twenty-five
Thirty-two
ZW-LZB-32SD
Two hundred and ninety
Forty
Seventy-four
Thirty-two
Forty
ZW-LZB-50SD
Three hundred and forty-five
Sixty-three
Ninety-eight
Fifty
Sixty-five
Twelve, the selection of encoding:
ZW-LZB
-
caliber
function
Description (Zhongwei control)
DN2-100
caliber
No label
Ordinary type
F
Corrosion proof type, PTFE base (for DN2~DN10) or carbon steel flange lining PTFE
B
All stainless steel material: 304 stainless steel
B0
All stainless steel material: 316 stainless steel
F/B (B0)
Type: stainless steel corrosion-resistant stainless steel flange (304 or 316) lined with PTFE (for DN15~DN100)
W
Food grade sanitary clamp;
S
Ordinary plastic type
SD
Plastic tube type
ZW-LZB
-
.
.
Zhongwei rotor flowmeter
Eleven, ordering:
1, according to the measurement of the fluid is a gas or liquid, the correct selection of ZW-LZB rotor flowmeter.
2, the measured fluid is non corrosive with ordinary type, corrosive resistant type selection.
3, please specify when ordering the names, the measured flow rate, pipe diameter and pressure, temperature, density, viscosity, etc..According to the user's density of correction, making special flow gauge.
4, according to the measurement range and measured fluid applications such as choosing the suitable type of the specifications.As the special requirements of the flowmeter, or call the sales department, and company.
Customer service service commitment:
1, our series of flowmeter series product quality problems occur in less than twelve months, is responsible for free repair.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, the warranty period after the product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.