High Temperature and High Pressure Magnetically Turned Plate Level Meter

17高压高压磁翻板液位计01.jpg
  • 17高压高压磁翻板液位计01.jpg
High-temperature and high-pressure magnetic tilting plate level gauge is suitable for liquid level m…

Description:

Productoverview:

ZW-UHZ series <strong> high temperature high pressure type magnetic level gauge</strong> can broaden the scope of use of the UHZ series, more widely to meet electricity, heat and gas industry requirements, using a unique cooling mode, can effectively control the dielectric instrument working temperature, avoid the magnetic element in high temperature conditions to ensure that the instrument is reliable and demagnetization. Capable of measuring high temperature of 450 DEG C, high pressure 25MPa.

The measurement and control of liquid level, suitable for high temperature and high pressure liquid container. Clearly indicates the height of the liquid level display, visual indicator, and the tank is completely isolated, the advantages of safe use, reasonable design, simple structure, convenient installation and reliable, stable performance, long service life, low maintenance cost, convenient installation and maintenance etc..

The user can according to the needs of the project, with the use of remote transmitter, can realize local digital display, and the output of the 4~20mA standard, with far EasTone, recording instruments, or industrial process control needs.You can also cooperate with the magnetic control switch or proximity switch used for liquid level monitoring alarm or the inlet fluid control equipment.

Two, work principle:

1, the basic type

ZW-UHZ series <strong> high temperature high pressure type magnetic level gauge</strong> according to the principle of buoyancy, the float with the liquid level measuring tube at the lifting up and down inside the float magnet by magnetic coupling effect, driving the red and white flip turn column 180 'level rises, turn column turned from white to red, down, turn by column red to white, so as to achieve the level of instruction.

2, limit switch output

The use of magnetic float with the liquid level gauge is installed in the mobile, the vertical tube set position switch, realize on-off control or alarm.

3, the electric remote

The magnetic level gauge transmitter installation. The sensor and transmitter converter is composed of two parts, the magnetic float moves up and down by the magnetic coupling of the measuring element in intraductal action, obtain the resistance signal changes, summoned into 0~10 or 4 ~ 20mA standard current signal output, and digital display connected to the instrument or computer, realize remote display and control.

Three, application:

ZW-UHZ series <strong> high temperature high pressure type magnetic level gauge</strong> is suitable for industrial production in the process of pressure (or open) liquid storage equipment (tower, cylinder, tank, spherical container and boiler) of the liquid level detection. Can display the work and all kinds of liquid level height. The position signal transmitter can teleport with level, achieve the automatic control and measurement of liquid level by certain electrical installations.

Four, main features:

1, strong sealing performance, easy penetration by special interface processing, more suitable for liquid high permeability occasions.

2, high temperature and high pressure resistance ability, large temperature of 600 DEG C, the pressure can reach 25MPa.

3, the corrosion resistance of stainless steel - lined with PTFE technology, the super anti-corrosion products.

4, can be used with special - jacketed process in low temperature applications, minus 200 occasions can handle it.

5, remote signal ability - signal output can switch analog, with HART protocol.

Five, technical parameters:

Measuring range: 150 ~ 15000mm;

Accuracy: + 10mm;

Working pressure: pressure to 25MPa;

Working temperature: -200 to 600 DEG c;

Medium density: 0.5 ~ 2 g/cm3;

Medium density difference: = 150kg / m3 (measurement interface);

The environmental vibration frequency is less than or equal to 25Hz amplitude less than 0.5mm;

Follow the speed: less than 0.08m/s;

Medium viscosity: less than 0.4Pa.S (can be used to improve the viscosity of jacket heat conditions);

Process connection:

Side mounted flange: DN25 / PN1.0, PN1.6, PN2.5/HG20592 ~ 20635-97;

Top loading flange: DN100 / PN1.0, PN2.5 / PN1.0 PN2.5 DN100 convex or convex, /HG20592 ~ 20635-97; or the installation size specified by the customer.

Texture of material:

LED tube: 1Cr18Ni9Ti; 304; 316L; PP; PVC; PTFE;

Float: titanium; PTFE.

Six, additional option:

1, the magnetic limit switch:

Open type: alarm with higher than;

Normally closed type: higher than the alarm off;

Switch capacity: 250VAC1A (resistive) 250VAC0.3A;

Switch life: 100000 times.

2, a liquid level transmitter:

Output current: 4-20mADC;

Resolution: + 1- + 10mm;

Load resistance: 500 ohms (24VDC power supply);

Transmission distance: 3000m;

Power supply: 16-30VDC.

3, intelligent liquid level transmitter:

Output current: 4-20ADC;

Resolution: 0.2mm;

Load resistance: 500 ohms (24VDC power supply);

Transmission distance: 3000m;

Power supply: 16-30VDC.

Seven, system components and wiring:

1, limit switch output:

A self holding function and reed switch converter, reed switches and converters were installed in the field and control room, by the converter to provide three pairs of contact switch.

2, the electric remote:

A measuring unit and a transmission unit is composed of two parts.

3, explosion-proof:

A with explosion-proof, upper and lower limit switch output:

Safety explosion-proof switch gate switch and relay contacts of the reed which can be directly provided to users of a normally closed or open contact. If the user needs to contact more special design orders. (Figure three)

With the explosion of the remote type security b:

Suitable for use in class II (Electrical Equipment Factory), C gas, the surface temperature of group T4 (135 C).

Note the use of c:

The shell is provided with external transmitter, users must be reliable grounding.

The use of the safety gate shall comply with the instructions for use of content.

The connecting cable transmitter and barrier for industrial safety end for two core shielded cable, wire cross-sectional area of more than 0.5m, cable distributed capacitance is 0.8 F.

Eight, installation, use and maintenance:

1, level gauge must be installed vertically, to ensure that the magnetic float movement in the main duct freely up and down.

A stop valve is arranged between the 2, the liquid level meter and the container, so that cleaning and maintenance to cut materials.

3, level gauge cylinder around a magnet close to not allow, otherwise it will directly affect the level of normal work.

4, level meter factory general insulation, but according to user needs for insulation, such as the user uses the hot mix line, must use the non-magnetic material.

5, to prevent the magnetic float transport at the leading high speed sliding tube to be hit, level meter factory, with Cathy will be fixed on the lower magnetic float liquid guide pipe, the user should be removed card silk can be installed prior to installation and use.

6, level meter installed, with magnetic correction of magnetic guidance once to zero below zero above the red, white

7, level gauge is put into operation, should open the valve on the liquid guide pipe, then slowly open under the liquid guide pipe valve, let the liquid medium smoothly into the main canal, avoid the liquid medium with a rapid rise caused by magnetic reversal failure or disturbed (in case of this phenomenon, the magnet available for calibration.)

8, open the bottom flange plate is installed in the magnetic float boring, heavy, should pay attention to end with a magnetic end up not flip.

9, level gauge cylinder should be solid impurities and magnetic impurities, so as to avoid jamming and weaken the buoyancy of the float.

10, according to the media, the leading tube can be cleaned regularly, remove sediment impurities in pipe.

Nine, the installation process:

1, after the factory, has assembled all the debugging, arrived at the scene, the first step must first clean up *, the need to install the equipment.

2, ready to install the necessary tools and bolts and manufacturers and distribution of the turning column indicates the calibration bar.

3, wipe scene flange, adjust equipment flange and magnetic level gauge flange on the straight, must keep the magnetic level gauge body vertical, and then put into the 4 hole bolt flange tool.

Ten, installation notes:

1, level gauge must be installed vertically, to ensure that the floating ball components in the main tube moving up and down freely.

2, level gauge around the main body does not allow the magnetizer near or directly affect level meter to work correctly.

3, level meter installed, need to use steel to correct a double bead guide to make zero position below zero above the display shows a red, white.

4, level meter running should first open the liquid guide pipe valve for liquid medium smoothly into the main pipe, avoid liquid medium with floating ball components caused by the rapid rise, turn turn bead failure and shuffle. If this occurs to the surface smooth available after re correction magnet.

5, due to the transport process in order not to float the component damage, before the factory will float out of the main pipe component level meter, liquid meter after installation, open the bottom discharge flange, then float assembly back in the main tube, pay attention to a heavy floating ball assembly on the head, not flip.

6, according to the media, can regularly open the sewage main pipe flange cleaning sediment.

Eleven, the selection of encoding:

ZW-UHZ-

A series of magnetic level gauge (Zhongwei control)

 

Basic types

Fifty-one

Magnetic indicator


Fifty-two

Magnetic indicator - Remote output


A

Basic type ( Side mounted )

B

Insulation type (jacket) S Frost proof R Electric heating type

C

Insert type (top mounted)

D

Corrosion proof type (side mounted anti-corrosion type)

E

Insert (top mounted type heat insulation type)

F

Insert the anti-corrosion type (top mounted anti-corrosion type)

G

Heat resistant type


One

No alarm

Two

belt One Only the alarm point

Three

belt Two Only the alarm point

Four

belt Three Only the alarm point

Five

belt Four Only the alarm point


Five

Stainless steel

 

The main materials

Six

Corrosion protection of aluminum

Seven

titanium

Eight

PVC

Nine

PTFE package


A

-40-0 C

 

working temperature

B

Less than or equal to 80 C

C

Less than or equal to 100 C

D

Less than or equal to 150 C

E

Less than or equal to 300 C

F

Less than or equal to 350 C

G

Less than or equal to 480 C


A

0.6 Mpa


 

The actual pressure

B

1 Mpa


C

1.6 Mpa


D

2.5 Mpa


E

4 Mpa


F

6.3 Mpa


G

10 Mpa


H

16 Mpa


I

22 Mpa


J

32 Mpa




L

The proportion of medium (g/ M)

L

Length measurement

L

The connecting flange ( DN )

L

output signal 4-20mA

Twelve, please provide the following data:

1, specifications; magnetic level gauge: ZW-UHZ series;

2, the measured medium Name: medium density: if you do not know the density, can tell us the name of the medium, which is composed of mixed liquid to know several liquid;

3, the instrument measuring range: also known as nominal length, which is the two flange center distance, or look at the scale of products already in use;

4, working pressure: pressure;

5, working temperature: measure the temperature of the liquid;

6, material requirements: wetted materials, such as do not know what kind of material, can give us advice (general liquid is what material we can use what material);

7, supporting the supply of flanges, bolts and nuts, valve, sealing washers and other accessories;

8, standard: flange flange nominal diameter, using conventional flange is DN20 or DN25;

9, special requirements: please indicate in detail before ordering, such as whether or not to take the remote, insulation jacket etc..

Customer service service commitment:

1, our level meter series products quality problems within twelve months, responsible for free maintenance.

2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.

3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.

4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.

5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


Browse:
Return To The Top

分享到: