Thermal insulating magnetic turning plate level gauge
The thermal insulation type magnetic turning plate level gauge is a heat preservation jacket install…
Description:
Productoverview:
ZW-UHZ-51B seriesInsulation type magnetic level gaugeIs the magnetic float as the measuring element, driving magnetic turning column display, without energy.Is suitable for measuring the antifreeze, insulation and heating occasions level, clamp type steam jacket, water jacket, electric vacuum jacket, jacket etc..According to the requirement of explosion-proof electric heating system.Is the ideal level measurement products such as petroleum and chemical industry.Configuration of upper and lower limit switch output magnetic float gauge, can realize remote alarm, limit control.To configure the transmitter magnetic float level meter, which can realize liquid level detection and control, remote indication.According to the installation position in the container, side loading and top loading two forms.According to different working mediums, provide stainless steel and engineering plastic ABS two materials; the ABS is especially suitable for acid, alkali and other corrosive medium.
Two, work principle:
1, the basic type
ZW-UHZ-51B series <strong> thermal insulation type magnetic level gauge</strong> according to the principle of buoyancy, the float with the liquid level measuring tube at the lifting up and down inside the float magnet by magnetic coupling effect, driving the red and white flip turn column 180 'level rises, turn column turned from white to red, down, turn column by red turn white, in order to achieve the level of instruction.
2, limit switch output
The use of magnetic float with the liquid level gauge is installed in the mobile, the vertical tube set position switch, realize on-off control or alarm.
3, the electric remote
The magnetic level gauge transmitter installation.The sensor and transmitter converter is composed of two parts, the magnetic float moves up and down by the magnetic coupling of the measuring element in intraductal action, obtain the resistance signal changes, summoned into 0~10 or 4 ~ 20mA standard current signal output, and digital display connected to the instrument or computer, realize remote display and control.
Three, application:
ZW-UHZ-51B series <strong> thermal insulation type magnetic level gauge</strong> and production level control switch and a liquid level remote transmission device supporting the use of liquid level remote control and display.The liquid level measurement and control so it is widely used in electric power, petroleum, chemical, metallurgy, shipbuilding, construction, environmental protection, food and other industries in the production process.
Four, main features:
1, the container is not suitable for side hole and surrounding the container space is small, can install the form level meter in the upper or lower container;
2, applicable to the viscosity of the liquid medium;
3, observe the direction of the display can be arbitrarily changed;
4, the installation level switch transmitter and a control switch, without stopping the machine can be installed at any time to adjust;
5, if the power fails, the scene switches.High accuracy is not affected;
6, every 10 minutes with the different colors of the liquid, the liquid is easy to identify.
Five, technical parameters:
1, the range (mm): 300~81000;
2, medium density (g/cm3): 0.5 ~ 2;
3, medium viscosity: less than 0.02Pa.S;
4, working temperature: -40 ~ 350;
5, pressure level (MPa): less than 32;
6, the measurement accuracy (mm): less than 10;
Installation: 7, side mounted, top mounted, bottom mounted;
8, protection grade: IP65;
9, explosion-proof grade: IB II CT4 (Ben Anxing), D II (BT4 flameproof);
10, transmission mode: 4 ~ 20mA or switch;
11, PN4.0: DN25 (HG20593 interface flange side mounted DN100 HG20593 (PN1.0) top mounted, bottom mounted), according to the needs of users can be customized.Note: when installed under the influence of environment security level gauge, the space position of L1<300 order should be significantly raised.
Six, additional option:
Limit switch:
Open type: alarm with higher than
Normally closed type: higher than the alarm off
Switch capacity: 250VAC1A (resistive) 250VAC0.3A
Switch life: 100000 times
Liquid level transmitter:
Output current: 4-20mADC
Resolution: + 1- + 10mm
Load resistance: 500 ohms (24VDC power supply)
Transmission distance: 3000m
Power supply: 16-30VDC
Intelligent liquid level transmitter:
Output current: 4-20ADC
Resolution: 0.2mm
Load resistance: 500 ohms (24VDC power supply)
Transmission distance: 3000m
Power supply: 16-30VDC
Seven, choose the type of:
1, steam jacket and circulating water jacket: in the gauge tube body adds a layer of cylinder, steam, circulating water or heat conducting oil circulation;
2, a vacuum jacket: in the gauge tube body adds a layer of vacuum tube, so that the measured medium and external insulation;
3, the electric jacket is in the liquid level meter main tube outer winding electric heating line circle, electricity for heating medium;
The user can according to the needs of the project, with the use of remote transmitter, can realize local digital display, and the output of the 4~20mA standard, with far EasTone, recording instruments, or industrial process control needs.You can also cooperate with the magnetic control switch or proximity switch used for liquid level monitoring alarm or the inlet fluid control equipment.
The measurement and control of liquid level, the interface is suitable for all kinds of liquid container.Clearly indicates the height of the liquid level display, visual indicator, and the tank is completely isolated, the advantages of safe use, reasonable design, simple structure, convenient installation and reliable, stable performance, long service life, low maintenance cost, convenient installation and maintenance etc..
Eight, use and maintenance:
Use:
1, auxiliary instrument and accessories with the specific content of the corresponding instrument and accessories see instructions.
2, to prevent a distance or move away in the process of float moves up and down in the main duct damage, lateral supporting special steel factory calibration gauge (with color logo) will hold the magnetic float.So after receiving the product or after installation, please remove the correction magnet, so that the float can move along with the liquid level, before use if the magnetic reversal of inconsistent color correction, available the magnetic suction along the instrument can work normally.
3, level meter installed, with magnetic correction of magnetic guidance once to zero below zero above display red, white display.
4, level gauge according to user needs with a heating jacket or an electric heating device, such as when ordering does not select this option, and in the installation of self used heat pipe, temperature and mixed with heat generated by the device can not exceed the rated temperature level meter.
5, level meter into travel, should open the valve on the liquid guide pipe, and then, the liquid valve open long, let the liquid medium smoothly into the main canal, avoid the liquid medium with a rapid rise caused by magnetic reversal failure or disturbed (in case of this phenomenon can be used to correct the magnet).
Maintain:
1, level gauge cylinder should be solid impurities and magnetic impurities, so as to avoid jamming and weaken the buoyancy of the float.
2, according to the media, the leading tube can be cleaned regularly, cleaning tube deposition of impurities.
3, clean or replace the float on the liquid, open the drain flange into the magnetic float, should pay attention to the heavy and magnetic end up not flip!
4, the low temperature liquefied gas and special products, vacuum jacketed insulation main body level meter, the installation process be careful not to damage the jacket, so as not to affect the quality of the products.
Nine, selection and installation:
1, we must first understand the equipment running their own situation, what is the measuring medium, even if they do not need to know what material, our company also can determine the material according to the medium used equipment.
2, when equipped with the remote meter to do the following, should make the remote meter to gauge leading tube, stainless steel hoop is fixed (disable iron); the remote meter should be on the surface should be oriented and close to the main duct; the remote meter should be zero and gauge zero instructions in the same horizontal line; remote meter and display instrument or computer connection alone wear protective pipe laying or shielding two core cable connection box; a wire inlet hole after laying, requires good sealing, in order to avoid rain, moisture intrusion and make remote matching instrument can not work normally, the junction box in the repair or completion of commissioning should be timely cover.
3, according to the media, cleaning the main duct to remove impurities;
4, for more than a certain length (common type > 3 meters, 2 meters, anti-corrosion type) of the liquid level meter, need to increase the middle reinforcement flange or lug fixed support, to increase the strength and overcome their weight;
5, magnetic position, board level meter should be avoided or away from materials import and export department, to avoid the rapid change of fluid material in local area, affecting the accuracy of liquid level measurement;
6, when debugging, should open the upper guide pipe valve, and then slowly open the valve at the lower part, so that medium smooth entry duct (to avoid the rush of media should be run in the float float, cause drama column fluctuation, affecting the display accuracy), observe the red ball magnetic flip is normal, and then close the lead pipe valve, open the drain valve so, the main duct level drops, according to the method, the operation three times, it is normal, can be put into operation (except special corrosive liquid); magnetic level gauge in the market there are other names, also called magnetic level gauge, or magnetic level gauge, also called magnetic float liquid level gauge.But they need to know the order parameter is certain, such as corrosive medium needs anticorrosive material, corrosion corrosion grade equivalent grade according to the changes of the medium.For example, the special situation of their own equipment, determine the installation mode of the magnetic level gauge, because some places do not fit or do not apply some installation methods.
Ten, the installation process:
1, after the factory, has assembled all the debugging, arrived at the scene, the first step must first clean up *, the need to install the equipment.
2, ready to install the necessary tools and bolts and manufacturers and distribution of the turning column indicates the calibration bar.
3, wipe scene flange, adjust equipment flange and magnetic level gauge flange on the straight, must keep the magnetic level gauge body vertical, and then put into the 4 hole bolt flange tool.
Eleven, installation notes:
1, level gauge must be installed vertically, to ensure that the floating ball components in the main tube moving up and down freely.
2, level gauge around the main body does not allow the magnetizer near or directly affect level meter to work correctly.
3, level meter installed, need to use steel to correct a double bead guide to make zero position below zero above the display shows a red, white.
4, level meter running should first open the liquid guide pipe valve for liquid medium smoothly into the main pipe, avoid liquid medium with floating ball components caused by the rapid rise, turn turn bead failure and shuffle.If this occurs to the surface smooth available after re correction magnet.
5, due to the transport process in order not to float the component damage, before the factory will float out of the main pipe component level meter, liquid meter after installation, open the bottom discharge flange, then float assembly back in the main tube, pay attention to a heavy floating ball assembly on the head, not flip.
6, according to the media, can regularly open the sewage main pipe flange cleaning sediment.
Twelve, the selection of encoding:
ZW-UHZ-
A series of magnetic level gauge (Zhongwei control)
Basic types
Fifty-one
Magnetic indicator
Fifty-two
Magnetic indicator-Remote output
A
Basic type(Side mounted)
B
Insulation type (jacket)SFrost proofRElectric heating type
C
Insert type (top mounted)
D
Corrosion proof type (side mounted anti-corrosion type)
E
Insert (top mounted type heat insulation type)
F
Insert the anti-corrosion type (top mounted anti-corrosion type)
G
Heat resistant type
One
No alarm
Two
beltOneOnly the alarm point
Three
beltTwoOnly the alarm point
Four
beltThreeOnly the alarm point
Five
beltFourOnly the alarm point
Five
Stainless steel
The main materials
Six
Corrosion protection of aluminum
Seven
titanium
Eight
PVC
Nine
PTFE package
A
-40-0C
working temperature
B
Less than or equal to 80C
C
Less than 100C
D
Less than or equal to 150C
E
Less than or equal to 300C
F
Less than or equal to 350C
G
Less than or equal to 480C
A
0.6 Mpa
The actual pressure
B
1 Mpa
C
1.6 Mpa
D
2.5 Mpa
E
4 Mpa
F
6.3 Mpa
G
10 Mpa
H
16 Mpa
I
22 Mpa
J
32 Mpa
L
The proportion of medium(g/M)
L
Length measurement
L
The connecting flange (DN)
L
output signal4-20mA
Thirteen, please provide the following data:
1, specifications; magnetic level gauge: ZW-UHZ series;
2, the measured medium Name: medium density: if you do not know the density, can tell us the name of the medium, which is composed of mixed liquid to know several liquid;
3, the instrument measuring range: also known as nominal length, which is a flange of the center distance, or look at the scale of products already in use;
4, working pressure: pressure;
5, working temperature: measure the temperature of the liquid;
6, material requirements: wetted materials, such as do not know what kind of material, can give us advice (general liquid is what material we can use what material);
7, supporting the supply of flanges, bolts and nuts, valve, sealing washers and other accessories;
8, standard: flange flange nominal diameter, conventional flange are using DN20 or DN25;
9, special requirements: please indicate in detail before ordering, such as whether or not to take the remote, insulation jacket etc..
Customer service service commitment:
1, our level meter series products quality problems within twelve months, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.