Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.

400 C ultra high temperature rotary level switch (screw)

10超高温法兰安装阻旋式料位开关400℃A型.png
10超高温法兰安装阻旋式料位开关400℃C型.png
10超高温法兰安装阻旋式料位开关400℃B型.png
10超高温法兰安装阻旋式料位开关400℃D型.png
10超高温法兰安装阻旋式料位开关400℃X型.png
  • 10超高温法兰安装阻旋式料位开关400℃A型.png
  • 10超高温法兰安装阻旋式料位开关400℃C型.png
  • 10超高温法兰安装阻旋式料位开关400℃B型.png
  • 10超高温法兰安装阻旋式料位开关400℃D型.png
  • 10超高温法兰安装阻旋式料位开关400℃X型.png
ZW-UZK series 400 C Ultra high temperature rotary level switch (screw) The special seal design, with…

Description:

Productoverview:

ZW-UZK series 400 C Ultra high temperature rotary level switch (screw) The special seal design, with two layers of dust, and a clutch device to protect the motor, reliable work, internal the advantages of simple structure, convenient use and maintenance, simple torque adjustment, reliable performance, no torque loss is not affected by temperature, humidity and adhesion effect. Can be used for the measurement of solid particles and dust, suitable for the level of detection of dust particles and other particles with diameter less than the free flow of 10mm. The switch can be installed in the cabinet, the cellar and the shaft, can also be applied to control the filling level and control empty, it can prevent overfilling.

Two, work principle:

ZW-UZK series of <strong style="white-space: normal;"> 400 C ultra high temperature rotary level switch (screw)</strong> working principle is the use of permanent magnet motor drives the rotating blades when the detected material rises to leaf position, leaf rotation is blocked, the resistance to the terminal box detection device, detection device is a switch signal output, and cut off the blade stops rotating power.

When material falls, blade resistance disappears, the detection device depends on the tension of the spring back to its original state, the spring tension adjustment of different material proportion, the proportion of large adjustment of spring tension to strong, otherwise adjust to weak or weak zui.

Three, application:

ZW-UZK series of <strong style="white-space: normal;"> 400 C ultra high temperature rotary level switch (screw)</strong> for detection of solid materials (powder, granular) level of material field control device, its unique sealing design, strong overload protection ability and easy installation, which is widely used in cement, metallurgy, coal, grain, feed, iron and steel, power plants and other industries, especially in the conductive material and material properties (state, humidity, dielectric constant, density etc.) often change, dust and other materials limit alarm application performance, can be used for monitoring the level of material of solid material.

Four, main features:

1, full closed, the house can be used;

2, the unique design of the oil seal can prevent dust infiltration along the axis;

3, the torque is stable and reliable, cutting torque can be adjusted;

4, lightweight, easy to install;

5, leaves under heavy load, the motor rotation mechanism will automatically slip, protection from damage;

6, not from a tank on the whole group can be easily removed, check and repair the internal parts.

Five, technical parameters:

1, power: 220VAC/110VAC/24VAC 50Hz/60Hz;

2, power: 3W;

3, contact capacity: 8A /250VAC SPDT;

4, working temperature: -10~80 degrees (special customized Zui up to 400 DEG C, imported up to 1000 DEG C);

5, blade speed: counter clockwise 1rpm;

6, torque: 1N.m;

7, the proportion of suitable material: more than 0.4g/cm3;

8, protection grade: IP65;

9, blade material: SUS304;

10, outlet: M20 * 1.5.

Six, torque adjustment:

1, according to the detected material density is different, need to adjust the tension torsion spring, torsion spring tension to the strong Zui proportion is large, and weak to.

2, do not arbitrarily change the torsion spring, so as to avoid misoperation.

Seven, installation requirements:

1, before installation, please confirm whether the supply voltage is above consistent with logo.

A switch should be installed in the inlet to avoid 2, impeding, when cannot avoid installation of a protective barrier, to protect the blade from the material impact.

3, the level of installation, wiring box line inlet should be vertical downward, cable fixing nuts must be locked, if the conditions can add fangyuzhao etc..

4, confirm the installation level before or vertical installation.

5, the level of the installation of blade and level was down 10 ~ 20O angle of installation, to reduce the impact of the material. 6, according to the different detecting material density, need to adjust the tension of the torsion spring, torsion spring tension to the strong Zui proportion is large, and weak to.

7, do not arbitrarily change the torsion spring, so as to avoid misoperation.

8 encoding selection:

Specification code

Name

ZW-UZK-

Impeding level switch (Zhongwei control)


AA

T type (spade type) Sixty-five * Eighty (width * height)

Leaf form


BA

Square (rectangular) One hundred * Forty (width * height) 80. * Thirty (width * height)


CA

Knife type (scimitar) Length detection 220mm The diameter of detection; 180mm


DA

L type (sickle)



XA

X (cross)




One

Ordinary type

Two

Axis protection tube type

structural style



Three

Long axis adjustable type

Four

Long-length




One

Screw installation

The installation form




Two

Flange mounting





EX

Flameproof : D II BT4

option





H1

High temperature type: process temperature : = 200 C





H1

Ultra high temperature: temperature That is less than or equal to 400 C





Y1

Power supply: AC 110VAC (220VAC Don't write)





Y2

Power supply: AC 24VAC (DC24VDC )





()

Other requirements please note

Nine, design selection and ordering information:

1, please indicate the measured medium, density, size, pressure, temperature, height of bin bin;

2, the installation can be installed lateral or vertical installation. High range vertical installation, the user can according to the measured depth of order extended (for 1 soft sleeve meters above the range);

3, detection of blade specifications, the factory is generally supporting materials according to the proportion of sand. If the measured medium than 4, lighter weight, leaf should use larger (please specify);

5, the medium temperature is 80-300 degrees centigrade, please choose the temperature type (please specify when ordering);

6, explosive dust (such as flour processing and storage), please choose the explosion-proof type (the installation.).

Customer service service commitment:

1, our level switch series product quality problems within twelve months, responsible for free maintenance.

2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.

3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.

4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.

5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


Browse:
Return To The Top

分享到: