Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
Tel:0517-86918678
Fax:0517-86918679
Email:zhongweick@163.com
Post Encoding:211600
WSS series The radial type double metal thermometer Is a kind of field measurement for middle and lo…
Description:
Productoverview: WSS seriesThe radial type double metal thermometerIs a kind of field measurement for middle and low temperature measuring instrument, can be used for direct measurement of gas, liquid, and vapor temperature.The thermometer from the design principle and structure of waterproof, anti-corrosion, explosion-proof, anti vibration, intuitive, easy reading, no mercury damage, durability and other characteristics.The protection tube, joint bolts are made of stainless steel materials, aluminum case with the machined surface black electrophoresis processing, table structure and table box sealing rubber ring by ring double screw cap, the meter overall waterproof anti-corrosion performance is good, with a pipe type structure radial type instrument, novel appearance, lightweight and beautiful out of the ordinary. Two, work principle: WSS seriesThe radial type double metal thermometerIs the principle of expansion work in varying degrees of temperature change when using two different metals.Industrial use of double metal thermometer main element is one with two or more metal sheet laminated together to form a multilayer metal sheet.In order to improve the measurement sensitivity of double metal thermometer, usually made of sheet metals of spiral shape.When the multilayer metal sheet temperature changes, each layer of metal expansion or shrinkage range, so that the spiral rolled up or loosen.Since the end of the spiral coil is fixed and the other end and a pointer can rotate freely. Therefore, when the feeling of double sheet metal to temperature changes, in a pointer to the circular indexing on the gauge indicates the temperature to. Three, application: WSS seriesThe radial type double metal thermometerIt can directly measure the production process in a variety of -80 to +500 DEG C range of liquid, steam and gas temperature.Widely used in petroleum, chemical, machinery, shipbuilding, power, textile, printing and dyeing industry and scientific research departments.
Fourth, the main features: 1, the scene display temperature, convenient safe and reliable, long service life; 2, a variety of forms, can meet different requirements.Victims of mercury free, easy reading, strong shock. 3, the protection pipe of 1Gr18Ni9Ti stainless steel and two molybdenum titanium, pressure, strong corrosion resistance. 4, core pulling type thermometer can not stop short time maintenance or replacement of movement. 5, integrated with axial, radial type, 135 o, universal type, complete varieties, suitable for various on-site installation need. Five, technical parameters: 1, the implementation of standards: JB/T8803-1998 GB3836-83; 2, dial diameter: 60100150; 3, accuracy: (1, 1.5); 4, thermal response time: less than 40S; 5, protection grade: IP65; 6, adjust the angle error: adjustment angle error should not exceed the range of 1%; 7, return difference: double metal thermometer to the difference should be less than the absolute value of the basic error limit; 8, repeat: double metal thermometer repeatability limit should be less than the absolute value of basic error of 1/2.
Six,Matters needing attention: 1, in storage, installation, use and transport process, to avoid the collision protection tube, prohibit the protection tube bending and deformation. 2, installation, non twist instrument shell. 3, the instrument shall work normally in the -30 to 80 DEG C ambient temperature. 4, the instrument can often work in the temperature scale range 1/2 ~ 3/4. 5, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, this is done in order to ensure the accuracy of measurement. 6, do not use media exposure in measuring container. 7, the process used to check the time, probably in about 6 months.
Seventh, temperature range:
The measuring range of C
Applicable scope
Industrial and commercial
Laboratory and small
-80 ~ +40
B.
B.
-40 ~ +80
B.
B.
0~50
B.
B.
0~100
B.
B.
From 0 to 150
B.
B.
0 ~ 200
B.
B.
0 ~ 300
B.
B.
0~400
B.
B.
0~500
B.
B.
Remarks: OneThe insertion depth of the thermometer,LMust be greater thanLmin,LAlternative series:One hundred,One hundred and fifty,Two hundred,Two hundred and fifty,Three hundred,Four hundred,Five hundred,Seven hundred and fifty,One thousand,One thousand two hundred and fifty,One thousand and five hundred,Two thousandSo, also can be customized according to user needs. TwoAnd the protective tube diameterPhi 6,Phi 8The series of thermometers, the time constant is less thanFortySecond, diameterPhi 10When the time constant is less thanThirtySeconds. ThreeProtect the stainless steel tube1Cr18Ni9TiManufacturing, at room temperature under high working pressure is Zui6.4MPa.
Eight, shape and size:
structural style
A
B
C
E
L
D
The axial type double metal thermometer
Sixty-five
Twenty-three
Seventy-three
-
Seventy-five One hundred One hundred and fifty Two hundred Three hundred Four hundred Five hundred Seven hundred and fifty One thousand
Phi 6 Phi 8 Phi 10
One hundred and five
Twenty-three
Seventy-three
-
One hundred and fifty-five
Twenty-three
Seventy-three
-
Sixty-five
Fifty
One hundred and ten
Thirty-four
One hundred and five
Fifty
One hundred and ten
Thirty-four
One hundred and five
Fifty
One hundred and ten
Thirty-four
135 degree to the type double metal thermometer
One hundred and five
Twenty-three
Eighty-five
-
One hundred and fifty-five
Twenty-three
Eighty-five
-
Universal type double metal thermometer
One hundred and five
Twenty-three
One hundred and seventy-eight
One hundred and twenty
One hundred and fifty-five
Twenty-three
One hundred and seventy-eight
One hundred and twenty
Nine, the specific model name description:
Model
Measuring range
Precision grade
Protection tube material
Specifications
Fixed form
D
L
WSS-310
-80 ~ +40 -40 ~ +80 0~50 0~100 From 0 to 150 0~200 0~300 0~400 0~500
One point five
1Cr18Ni9Ti Three hundred and four Three hundred and sixteen 316L Hastelloy C-276
Phi 60
Seventy-five One hundred One hundred and fifty Two hundred Three hundred Four hundred Five hundred Seven hundred and fifty One thousand
No fixed device
WSS-410
Phi 100
WSS-510
Phi 150
WSS-311
Phi 60
Movable external thread
WSS-411
Phi 100
WSS-511
Phi 150
WSS-312
Phi 60
The movable internal thread
WSS-412
Phi 100
WSS-512
Phi 150
WSS-313
Phi 60
Fixed thread
WSS-413
Phi 100
WSS-513
Phi 150
WSS-314
Phi 60
Fixed flange
WSS-414
Phi 100
WSS-514
Phi 150
WSS-315
Phi 60
Card set screw
WSS-415
Phi 100
WSS-515
Phi 150
WSS-316
Phi 60
WSS-416
Phi 100
Sleeve flange
WSS-516
Phi 150
Ten, the selection of encoding:
Serial number
WSS
Double metal thermometer (Zhongwei control)
Dial diameter
-3
Phi 60
-4
Phi 100
-5
Phi 150
Dial form
Zero
The axial (straight)
One
Radial (angle)
Two
135 degrees to (an obtuse type)
Eight
Universal (angle adjustable type)
Fixed form
Zero
No fixed device
One
Movable external thread
Two
The movable internal thread
Three
Fixed thread
Four
Fixed flange
Five
Card set screw
Six
Sleeve flange
Type of protection
-
Ordinary type
W
Type of protection
F
Anti-corrosion type
Eleven, design and ordering: Please provide the type, dial diameter, precision grade, fixed form, the range of temperature measurement, protection material, pipe length or depth of insertion. Customer service service commitment: 1, my company sold ZhongweiThermometer seriesThe product within twelve months of quality problems, responsible for free maintenance. 2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement. 3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost. 4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost. 5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.