Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
0517-86918678
Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
Tel:0517-86918678
Fax:0517-86918679
Email:zhongweick@163.com
Post Encoding:211600

The thermal resistance of remote bimetal thermometer

5电阻远传双金属温度计.PNG
  • 5电阻远传双金属温度计.PNG
WSSP series The thermal resistance of remote bimetal thermometer And the development of a series of …

Description:

Productoverview:
WSSP series The thermal resistance of remote bimetal thermometer And the development of a series of temperature instruments, to overcome the traditional thermometer single expansion performance and short service life and poor reliability, the disadvantages of large volume temperature package. The temperature sensor of steam and gas volume respectively than the traditional pressure type thermometer reduced by 30 and 60 times, creatively or platinum copper heat resistance temperature sensor mounted on the measuring element, realize the function of temperature measurement of electromechanical integration. Formed by the liquid pressure type temperature is extremely basic temperature measuring instrument for remote transmission, explosion-proof, anti-corrosion, shockproof, electrical connector, temperature signal transmission and other functions, a series of temperature meter.

Two, work principle:
WSSP series The thermal resistance of remote bimetal thermometer Is a kind of thermal resistance temperature sensor and WSSP type thermometer temperature package installed in the same temperature element within a temperature measuring instrument. Two measurement systems are independent of each other, do not affect the temperature measurement accuracy and their. The outstanding advantages of this instrument is just a single point temperature measurement can double indicate the measured temperature, the pressure for the instructions, the thermal resistance signal for transmission to the control room (about 500 meters), with two meter line, to control and adjust the measured temperature, the two temperature measurement system to monitor each other, improve the temperature measurement accuracy and reliability.
Three, application:
WSSP series The thermal resistance of remote bimetal thermometer Not only meet the temperature requirements, but also to meet the needs of long-distance transmission, remote double metal thermometer can directly measure the production process in a variety of -40 ~ +600 temperature range of liquid, gas and steam medium and solid surface temperature measurement.
Four, main features:
1, a temperature probe of small, high sensitivity, linear scale, long service life etc..
2, with remote output resistance signal (PT100), shock resistance, corrosion resistant function and large power switch signal etc..
3, structure and international similar products, can replace imported.
Five, technical parameters:
1, the temperature range of -40 to 600 DEG c;
2, the ambient temperature of -10 to 55 DEG c;
3, the relative humidity is less than or equal to 95%;
4, precision grade 1.5;
5, the time constant is less than or equal to 60S;
6, the probe voltage is less than or equal to 6Mpa;
7, probe diameter: 8-10mm diameter, movable external thread: M27*2;
8, thermal resistance PT100 (single channel, dual output or 4-20mA output current).

Six, matters needing attention:
1, in storage, installation, use and transport process, to avoid the collision protection tube, prohibit the protection tube bending and deformation.
2, installation, non twist instrument shell.
3, the instrument shall work normally in the -30 to 80 DEG C ambient temperature.
4, the instrument can often work in the temperature scale range 1/2 ~ 3/4.
5, the protective tube immersionmedium measured in length must be greater than the length of the sensing element, this is done in order to ensure the accuracy of measurement.
6, do not use media exposure in measuring container.
7, the use of the process should pay attention to check in time, probably in about 6 months.

Seven, technical data sheet: 

type Number

Graduation

The measuring range of C

Precision grade

Protection tube material

Insertion length

WSSE-401

E

-80 ~ +40

Forty ~+80

Zero ~Fifty

Zero ~One hundred

Zero ~One hundred and fifty

Zero ~Two hundred

Zero ~Three hundred

Zero ~Four hundred

Zero ~Five hundred

One point five

1Cr18Ni9Ti

Three hundred and four ;

Three hundred and sixteen; 

316L ;

Harrington

C-276

One hundred and fifty

Two hundred

Three hundred

Four hundred

Five hundred

Seven hundred and fifty

One thousand

WSSE-501

WSSE-411

WSSE-511

WSSE-481

WSSE-581

WSSP-401

Pt100

WSSP-501

WSSP-411

WSSP-511

WSSP-481

WSSP-581

WSSXE-401

E

WSSXP-401

Pt100

WSSXE-411

E

WSSXP-411

Pt100

WSSXE-481

E

WSSXP-481

Pt100

Eight, temperature range:

The measuring range of C

Applicable scope

Industrial and commercial

Laboratory and small

-80 ~ +40

B.

B.

-40 ~ +80

B.

B.

0~50

B.

B.

0~100

B.

B.

0~150

B.

B.

0 ~ 200

B.

B.

0 ~ 300

B.

B.

0~400

B.

B.

0~500

B.

B.

Remarks:
One The insertion depth of the thermometer, L Must be greater than Lmin , L Alternative series: One hundred , One hundred and fifty , Two hundred , Two hundred and fifty , Three hundred , Four hundred , Five hundred , Seven hundred and fifty , One thousand , One thousand two hundred and fifty , One thousand and five hundred , Two thousand So, also can be customized according to user needs.
Two And the protective tube diameter Phi 6 , Phi 8 The series of thermometers, the time constant is less than Forty Second, diameter Phi 10 When the time constant is less than Thirty Seconds.
Three Protect the stainless steel tube 1Cr18Ni9Ti Manufacturing, at room temperature under high working pressure is Zui 6.4MPa .

Nine, shape and size:

structural style

A

B

C

E

L

D

The axial type double metal thermometer

Sixty-five

Twenty-three

Seventy-three

-

Seventy-five
One hundred
One hundred and fifty
Two hundred
Three hundred
Four hundred
Five hundred
Seven hundred and fifty
One thousand

Phi 6
Phi 8
Phi 10

One hundred and five

Twenty-three

Seventy-three

-

One hundred and fifty-five

Twenty-three

Seventy-three

-

The radial type double metal thermometer

Sixty-five

Fifty

One hundred and ten

Thirty-four

One hundred and five

Fifty

One hundred and ten

Thirty-four

One hundred and five

Fifty

One hundred and ten

Thirty-four

135 degrees to type double metal thermometer

One hundred and five

Twenty-three

Eighty-five

-

One hundred and fifty-five

Twenty-three

Eighty-five

-

Universal type double metal thermometer

One hundred and five

Twenty-three

One hundred and seventy-eight

One hundred and twenty

One hundred and fifty-five

Twenty-three

One hundred and seventy-eight

One hundred and twenty

Ten, the selection of encoding:

Serial number

category

Specifications

Explain

WSS

P

Thermal resistance type

Double metal thermometer (Zhongwei control)

Dial diameter

-3


Phi 60

-4


Phi 100

-5


Phi 150

Dial form

Zero


The axial (straight)

One


Radial (angle)

Two


135 degrees to (an obtuse type)

Eight


Universal (angle adjustable type)

Fixed form

Zero


No fixed device

One


Movable external thread

Two


The movable internal thread

Three


Fixed thread

Four


Fixed flange

Five


Card set screw

Six


Sleeve flange

Type of protection

-


Ordinary type

W


Type of protection

F


Anti-corrosion type

Cases: The axial type, PT100 type, I temperature range of 0-400 DEG c.. Activity thread M27x2, protective tube insertion length is 316 300mm. WSSP-401 0-400 l=300mm I: C protection tube 316.

The design and selection of notes:
1, model;
2, the thermal resistance index number;
3, the thermal resistance precision grade;
4, double metal thermometer precision grade;
5, temperature range;
6, fixed form;
7, protection tube material;
8, the inserted length.
Customer service service commitment:
1, my company sold Zhongwei Thermometer series The product within twelve months of quality problems, responsible for free maintenance.
2, the warranty period if the products of our company have any quality problems, our company is responsible for free repair or replacement.
3, the warranty period if the user use undeserved, cause damage to the product, our company is responsible for the maintenance, collect the damaged parts cost.
4, after the warranty period of product quality problems, our company is responsible for the maintenance, collect the damaged parts cost.
5, if the user needs to our service, our company in the province of the user service personnel arrived at the scene within 12 hours, arrived at the scene 48 hours outside users.


Browse: