Isolated distributor is in the automatic control system for a variety of temperature transmitter, fl…

Description:

Products overview:
ZW - GLP seriesIsolation of distributorOffer at the scene of the transmitter isolation of dc power supply, and examined 4-20 ma current signal from the transmitter, after dealing with the isolation, interference resistance, etc.To the control system or other unit combination instrument output 4-20 ma dc current or voltage and other signals.
Second, the applications:
ZW - GLP seriesIsolation distributor is widely used in mechanical, electrical, power, petroleum, chemical, steel, sewage treatment in areas such as data acquisition, signal conversion, industrial measurement and control system, such as PLC, DCS, is used to improve and complement system simulation ∣ / O plugin function, increase the system applicability and reliability of field environment.
Three, the main features:
1, the single-chip microcomputer unique and powerful software function and isolator's own excellent hardware electrical properties for the stability and reliability of the product provides a solid guarantee.
2, the isolator can use communication protocol USES the means of communication and hand connection, online observation input, the output value.
3, without using zero and full of external potentiometer to digital signal automatic/manual adjustments.At the same time can be automatically compensate to the input signal.
4, intelligent isolator of the input signal is the high and low frequency interference signal provides the software on the suppression and processing.Even in high power frequency conversion control system is also capable of reliable operation.
5, single or double input for the linear current or voltage signal of the road.
6, analog output isolation of single, double current or voltage signal and the input, output, and provide a good electrical isolation between the power.
Four, the technical parameters:
1, the system transmission accuracy: + / - 0.2% x f. S.
2, temperature drift: 0.005% f. S / ℃ or less;
3, working temperature: industrial standards - 10 ~ + 55 ℃;
4, input impedance: current: 100 Ω;Voltage: 500 k Ω;
5, allowing external load impedance output current: 4-20 ma output 0 ~ 500 Ω;0 to 10 0 ~ 1 k Ω, the output of the ma need more load capacity when ordering, please;
6, electromagnetic compatibility: meet IEC61000-4 - and in 95 the fourth category specified in (a) bad industrial site environment on the product's resistance to electromagnetic interference requirements;
7, input/output/power/communication/double insulation strength: 1500 v or higher. The ac;
8, storage and transportation environment temperature: - 40 ~ + 80 ℃;
9, relative humidity: 10-90% RH (40 ℃);
10, power supply, communication: 95 ~ 265 v AC;
11, dc: DC12V ~ 32 v (reverse connect protection);
12, the input power: 0.9 ~ 1.8 W (related to the model, see the appendix to this manual calculation method about the input power);
13, communication interface, RS232 or RS485, MODBUS protocol software (optional).
14, overall dimensions: width * deep high: 22.5 * 100 * 115 mm;
15, net weight: 20 g to 140 g +.
Five, the working conditions:
Working temperature: 0 ~ 50 ℃
Storage temperature: - 40 ~ 85 ℃
Relative humidity: 10 ~ 90% RH
The atmospheric pressure: 86 ~ 106 kpa
Six, selection table:

model

said Ming

ZW-GLP-







General distributor

The input circuit

1


The default for single loop

2

Double circuit (isolated)

The input signal

1


4~20 mA

2

0~10 mA

3

0~5 V

4

1~5 V

5

0~10 V

6

0~20 mA

Operation output end * road

1


4~20 mA

2

0~10 mA

3

0~20 mA

4

1~5 V

5

0~10 V

6

0~20 mA

End of the first two output operation

0


Without the first 2

1

4~20 mA

2

0~10 mA

3

0~20 mA

4

1~5 V

5

0~10 V

6

0~20 mA

The third way output

0


There is no third way

1

4~20 mA

2

0~10 mA

3

0~20 mA

4

1~5 V

5

0~10 V

6

0~20 mA

Feed output


Default is passive

V24

withDC24VFeed output

The power supply mode

A

The default for communication220V

D

dc24V

Seven, selection of details:
1, only single channel product has alarm, communication function;
2, which has the function of alarm products, its upper or lower limit alarm value can be modified by programming, and alarm control detailed setting method refer to handheld programmer using manual.The default output for normally open point, relay for normally closed please order.

After-sales service commitment: 
1, our company sold by weiisolatorProduct quality problem within 12 months, responsible for free maintenance. 
2, the warranty period, any quality problems such as the products of our company, my company is responsible for free repair or replacement. 
3, the warranty period, such as user improper use, damaged products, my company is responsible for the maintenance, charge damage parts cost. 
4, after the warranty period appear quality problem, my company is responsible for the maintenance, charge damage parts cost. 
5, such as user need to my company site services, to users in the province I company service personnel to reach the site within 12 hours, fujian association of foreign languages and user reach the site within 48 hours.


Browse:
On A:No
Next:No
Return To The Top

分享到: