Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
Tel:0517-86918678
Fax:0517-86918679
Email:zhongweick@163.com
Post Encoding:211600
EJA130A High Static Pressure Differential Pressure Transmitter
EJA130A high static pressure differential pressure transmitter provides two Fieldbus modes, FOUNDATI…
Description:
A field bus communication ability: EJA130A high pressure differential pressure transmitterProvide two kinds of fieldbus, FOUNDATION fieldbus? Low voltage mode and PROFIBUS PA devices, to realize the collaborative work of Henghe motor and other suppliers.The software, SD series uses two AI function block calculation of differential pressure and static pressure, so as to realize flexible instrument configuration. Two, compact and lightweight design: EJA130A high pressure differential pressure transmitterThe ASIC amplifier design to make the packaging becomes small, and the miniaturization of the membrane structure and the flange of the box, this type of weight dropped to half of the original type.ASIC design not only reduces the number of parts, but also improve the reliability of the amplifier. Third, the main features: Silicon resonant sensor. High accuracy: + 0.075%; 5 years of continuous work without adjustment; The temperature effect is negligible; The static effects can be ignored. Effect: 100 thousand consecutive unidirectional voltage unidirectional overvoltage after the experiment affect the amount of less than 0.03%; The function of two-way communication (BRAIN/HART protocol, FF bus). Self diagnosis function perfect; A small, light weight (standard 3.9kg); Four, static effects are neglected: When a static pressure (pressure), resonant beam deformation two shape, size and material identical to the same, so the frequency change is consistent, so the deviation automatically cleared (figure similar formula and temperature influence). Excellent characteristics of unidirectional overvoltage: The liquid membrane and the membrane using corrugated box body processing technology of the original, so that the external pressure increases to a certain value, the film can fully contact with the body, silicone oil is transferred to the sensor pressure no longer increase with the increase of external force, so as to achieve the protective effect on sensor.
Five, selection table:
Basic specification code: EJA130A-DMS5A-92NN
First: output signal
-D4-20mA DC/BRAIN -E4-20mA digital communication protocol DC/HART protocol digital communication -FFF fieldbus communication
Article 2: the measurement range (film box)
M1-100KPaH5-500KPa
Third: wetted parts materials
SSUS316 SUS316L SUS316
Fourth: process interface
0 joints (Rc1/4 internal threads in the chamber flange) 1Rc1/4 internal thread process thread process joint internal thread joint 2Rc1/2 process 31/4NPT thread in process of joint 41/2NPT joint 5 joint process (1/4NPT internal thread in the chamber flange)
-2 vertical pipe connection, right upper pressure, the installation process of -3 vertical joints connecting pipes, the right pressure, lower installation joint -6 vertical pipe connection, left pressure, upper joint installation process -7 vertical pipe connection, left pressure, lower the level of -8 piping installation process joint connection, the right pressure level of -9 pipe connection, left pressure
Seventh: electrical interface
0G1/2 thread, a thread of 21/2NPT electrical interface, two electrical interface, no blind plug 3Pg13.5 internal thread, two electrical interface, no blind plug 4M20 internal thread, two electrical interface, no blind plug 5G1/2 internal thread, two electrical interface, a blind plug 71/2NPT internal thread, two electrical interface, a blind plug 8Pg13.5 internal thread, two electrical interface, a blind plug 9M20 internal thread, two electrical interface, a blind plug
Eighth: built-in display table
D E digital display table with a measurement range setting button digital display meter N
Ninth: mounting bracket
AJIS SECC BJIS SUS304 CJIS SECC flat bracket bracket bracket type L DJIS SUS304 L N type bracket