Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
Tel:0517-86918678
Fax:0517-86918679
Email:zhongweick@163.com
Post Encoding:211600
Single-seat regulating valve is a top-guiding structure of regulating valve. Its body fluid passage …
Description:
A brief introduction: HTS seriesSingle seat control valveIs a top guide structure regulating valve, the valve fluid channel was streamlined S, the pressure drop, flow rate, wide adjustable range and high precision valve flow characteristic curve, oriented area, good vibration resistance.The valve is equipped with multi spring diaphragm actuator, compact structure, large output force.Can be used to control various fluid pressure and temperature. Two,Single seat control valveThe performance: 1, leakage: metal seat: meet ANSIB16.104 IV, less than the rated Cv 0.01%; 2, soft seat: meet ANSIB16.104 VI, less than the rated; 3, quick opening valve: less than rated Cv 0.00001%; 4, return difference: 1% (with locator); 3% (without locator); 5, linear: + l% (with a locator); + 5% (without locator); 6, note: V PTFE standard; 7, adjustable range: 50 to L (Cv = 1) or 30 (Cv = 0.63): 1. Three,Single seat control valveThe main technical parameters: 1 types: direct single seat casting ball valve; 2, nominal diameter: 20, 25mm; 3, nominal pressure: SD-HLSI125, 150, 300, 600, 10, 16, 20; JIS, 30, 40K PNl.6, 4, 6.4MPa 4, connection type: flange type: FF, RF, RJ and LG; according to standard of ANSI Bl6.5, JISB2201JB/T79.1PNl.6MPa JB/T79.2, concave convex surface; 5, welding weld type: SW; 6 material: HT200ZG25 ZG1Cr18Ni9; ZG0Cr17Ni12Mo21.25Cr0.5Mo5.0Cr0.5Mo, SDPH21SCPH61Ti; 7, valve cover: normal temperature type (P):-l7 ~ +230 c; 8, elongation type 1 (E1):-45 ~ -17 ~ +566 C C, +230; 9, elongation of type II (E2): integral (E2I): -100 ~ -45 welding type C (E2W): -196-100 c; 10, gland type: bolt clamp; 11, packing: V PTFE, PTFE impregnated asbestos packing, asbestos braid packing. The four component, single seat control valve of the valve: 1, spool type: single seat plunger type valve; 2, flow characteristics: metal seat: Cv value from high precision flow characteristics of 0.4 ~ 14 with IEC534-2; The scope of work: 3, soft seat, working temperature and pressure welding division Chatterley working temperature and pressure difference; 4, material: 1Cr18Ni9 division stellite alloy surfacing 9Crl8MoV. Five, actuator: 1, type: HA multi spring diaphragm actuator; 2, the diaphragm material: rubber nylon clip; 3, spring range: 0.02 ~ 0.10, 0.08 ~ 0.24MPa; 4, air pressure: 0.14, 0.16, 0.28, 0.40MPa; 5, joint source: Rc l/4; 6, the environment temperature: -30 ~ +70 c; 7, valve type: gas - gas - open or closed; 8, annex: locator, hand wheel, pneumatic valve position transmitter. Six, value and travel:
Spool type
The seat and the flow characteristics
Rated travel
Zero point zero one
Zero point zero four
Zero point one
Zero point one six
Zero point two five
Zero point four
Zero point six three
One
One point six
Two point five
Four
Six point three
Ten
Fourteen
Plunger valve
Metal seat
The percentage (%)
14.3mm
2003
Delta
Delta
Delta
Delta
Delta
Delta
Delta
Delta
Delta
Linear (L)
2003
2003
2003
2003
2003
Delta
Delta
Delta
Delta
Delta
Delta
Delta
Delta
Delta
soft seat
The percentage (%)
2003
2003
2003
2003
2003
2003
2003
2003
2003
2003
Linear (L)
2003
2003
2003
2003
2003
2003
2003
2003
2003
2003
2003
2003
Nominal diameter
Twenty
B.
B.
B.
B.
B.
B.
B.
B.
B.
B.
B.
B.
Twenty-five
B.
B.
B.
B.
B.
B.
B.
B.
B.
B.
B.
B.
B.
B.
Note: 1, symbols, and delta said valve specifications.2, the symbol said the flow characteristic of the valve according to the standard of IEC 534-2. Seven, allow pressure: 1. The plunger valve, metal seat (%CF, LCF) A. gas - off valve 100KPa
Actuator
Air pressure
Spring range
Positioner
Allowable differential pressure
The rated value of Cv
Less than 0.25
Zero point four
Zero point six three
One
One point six
Two point five
Four
Six point three
Ten
Fourteen
DKA1D
One point four
From 0.2 to 1
With or without
40*
Thirty-one
Thirty-one
Sixteen
Sixteen
Ten
Ten
Five point six
Four point two
Two point six
Fifty-six
One point six
From 0.2 to 1
Yes
40*
40*
40*
40*
40*
40*
40*
Twenty-eight
Twenty-one
Thirteen
One hundred
One hundred
One hundred
Eighty-four
Eighty-four
Fifty-two
Fifty-two
Four
0.8 ~ 2.4
Yes
-
-
-
-
-
40*
40*
40*
40*
Thirty-nine
One hundred
One hundred
Eighty-four
Eighty-four
DKA2D
One point four
From 0.2 to 1
With or without
40*
40*
40*
Thirty-two point six
Thirty-two point six
Twenty
Twenty
Ten point nine
Eight point two
Five
One hundred
Sixty-two
Sixty-two
One point six
From 0.2 to 1
Yes
-
40*
40*
40*
40*
40*
40*
40*
40*
Twenty-five point two
One hundred
One hundred
One hundred
One hundred
One hundred
One hundred
Fifty-four
Four
From 0.8 to 2.4
Yes
-
-
-
-
-
-
-
40*
40*
40*
One hundred
One hundred
Seventy-five
B. gas valve open
Actuator
Air pressure
Spring range
Positioner
Allowable differential pressure
The rated value of Cv
Less than 0.25
Zero point four
Zero point six three
One
One point six
Two point five
Four
Six point three
Ten
Fourteen
DKA1R
One point four
From 0.2 to 1
With or without
40*
Thirty-one
Thirty-one
Sixteen
Sixteen
Ten
Ten
Five point six
Four point two
Two point six
Fifty-six
Two point eight
0.8 ~ 2.4
Yes
40*
40*
40*
40*
40*
40*
40*
Thirty-nine
Twenty-nine
Eighteen
One hundred
One hundred
One hundred
One hundred
One hundred
Seventy-two
Seventy-two
DKA2R
One point four
From 0.2 to 1
With or without
40*
40*
40*
Thirty-two point six
Thirty-two point six
Twenty
Twenty
Ten point nine
Eight point two
Five
One hundred
Sixty-two
Sixty-two
Two point eight
From 0.8 to 2.4
Yes
-
40*
40*
40*
40*
40*
40*
40*
40*
Thirty-five
One hundred
One hundred
One hundred
One hundred
One hundred
One hundred
Seventy-six
Fifty-six
Note: 1. does not exceed the maximum allowable pressure of ANSI B16.34 or JIS B2201 standard maximum working pressure. Figure 2. the same box above said valve is normally open to allow pressure, under the digital representation allows the differential pressure valve is fully closed when the. Allow pressure 3. with *, valve control liquid, allowing the pressure is only 3MPa, more than 3MPa, please use the LHLC valve. 4. ash bottom box number indicates valve equipped with standard actuator. Eight, flange from mm:
Nominal diameter
A
ANSI 125FF ANSI 150RF JIS 10K Ff, RF PN1.6
JIS 16K RF
ANSI 300RF JIS 20K RF JIS 30K RF PN4.0
ANSI 600RF JIS 40K RF PN6.4
ANSI 150 RJ
ANSI 300 RJ
ANSI 600 RJ
JIS 20K embedded type groove
JIS 30K embedded type groove
ANSI 300 LG
ANSI 600 SW, BW
Twenty
One hundred and eighty-four
One hundred and ninety
One hundred and ninety-four
Two hundred and six
-
Two hundred and six
Two hundred and six
One hundred and ninety-eight
Two hundred and eight
Two hundred and three
Two hundred and six
Twenty-five
One hundred and eighty-four
One hundred and ninety-three
One hundred and ninety-seven
Two hundred and ten
One hundred and ninety-seven
Two hundred and ten
Two hundred and ten
One hundred and ninety-eight
Two hundred and twelve
Two hundred and six
Two hundred and ten
Note: the flange from conforms to the IEC534-3 standard. Nine, size mm:
Actuator
H
Phi B
C
E
Room temperature P
Elongation type E1
Elongation of type II E2I
Elongation of type II E2W
DKA1D, R
Three hundred and seventy-five
Five hundred and twenty-five
Six hundred and eighty-five
Nine hundred
Two hundred and eighteen
,
230.
Forty
DKA2D, R
Four hundred and fifty
Six hundred
Seven hundred and sixty
Nine hundred and seventy-five
Two hundred and sixty-seven
Two hundred and eighty-one
Forty
Note: the H column is not size regulating valve with hand wheel, if the belt wheel mechanism to the corresponding plus hand wheel size. 10, flange:
Nominal diameter
Actuator
ANSI 125, 150 JIS 10K
ANSI 300, 600 JIS 16, 20, 30, 40K
Room temperature (P)
Elongation type (E1)
Elongation type (E2I)
Elongation type (E2W)
Room temperature (P)
Elongation type (E1)
Elongation type (E2I)
Elongation type (E2W)
20, 25
DKA1D, R
Sixteen
Eighteen
Twenty-one
Twenty-six
Seventeen
Nineteen
Twenty-two
Twenty-seven
DKA2D, R
Twenty-three
Twenty-five
Twenty-eight
Thirty-three
Twenty-four
Twenty-six
Twenty-nine
Thirty-four
Eleven, welding connection:
Nominal diameter
Actuator
Room temperature (P)
Elongation type 1 (E1)
Elongation of type II (E2I)
Elongation of type II (E2W)
20, 25 (SW)
SDA1D, R
Fourteen
Sixteen
Nineteen
Twenty-four
SDA2D, R
Twenty-one
Twenty-three
Twenty-six
Thirty-one
Design selection and ordering information: 1, product type and name; 2, the nominal diameter of DNmm; 3, nominal pressure; The requirements of 4, flow characteristics; 5, body material and trim materials; 6, medium type and temperature range; 7, valve and pressure (pressure difference); 8, seal form; 9, accessories.